Distance Sensor M74
Features
- Laser Sensor up to 10 kHz
- Range from 0,5 up to 2 mm
- Analogical triangulation sensor
- For high mirroring and transparent surfaces
- Small sensor head
|
| SENSOR |
M74L/0,5 |
M74L/2 |
| RANGE |
0,5 |
2 |
| RANGE BEGIN |
23,75 |
23 |
| LINEARITY ± (mm) |
0,001 |
0,004 |
| RESOLUTION ± (mm) |
0,00025 |
0,001 |
| LIGHT SPOT DIAMETER (mm) |
0,1 |
0,1 |
| LIGHT SOURCE |
Laser, wavelength 670 nm, red isible |
| SAMPLING FREQUENCY |
54 kHz/RS232/4....20 mA
|
| Output |
± 10 V |
Impedance
|
approx 0 Ohm (max. 10 mA) |
| Analogical outputs Angle error |
with 30° of inclination |
| Reaction time |
0,1....67 ms |
| Bandwith |
0,015...10 kHz (-3 dB) |
| Temperature drift |
0,02%/K of range |
| Intensity output |
0...10 V |
| MIN |
+24 V / 10 mA when lower than MIN, LED giallo |
| OK |
+24 V / 10 mA when higher than MIN and lower than MAX, LED verde |
| Digital
outputs
MAX |
+24 V / 10 mA when higher than MAX, LED arancione |
| Option |
Relay output 0,5 A / 100 V for „MIN“, „OK“ and „MAX“ |
| Error |
+24 V / 10 mA when too less light, LED rosso |
| AMBIENT LIGHT |
20.000 Lux |
| OPERATING TIME |
50.000 h for the laser diode |
| OPERATING TEMPERATURE |
0°....+50° C |
| STORAGE TEMPERATURE |
-20°....+ 70°C |
| HUMIDITY |
up to 90% RH |
| PROTECTION |
Sensor : IP64
Electronic module : IP40 |
| SUPPLY |
+ 24 VDC/200 mA (10....30 V) |
Delivery :
- Sensor with connection cable 2 m
- Electronic system
- 25 pin D-Sub-connector for output, soldering version
- Calibration Certificate
|
Accessoires :
- Thickness measurement system
- High laser power
- Protection
- Interface filter
- Power supply
- supply cable
- Digital display
|
Options :
- Special cable length
- Cable output on the right side
- Sensor head with integrated protection glass
- Sensor head vibration resistant
|
|
CONTROLLER M74

|
 |
|